Reference ProLinx-HART ♦ ProLinx Gateway
Driver Manual HART Master with Analog I/O
Page 54 of 104 ProSoft Technology, Inc.
October 13, 2011
COMMAND 19 - Write Final Assembly Number
Description
This command writes the final assembly number of the HART device.
Write Parameters
Word High Byte Low Byte
0 Final Assembly Number 0 Final Assembly Number 1
1 Final Assembly Number 2 Final Assembly Number 2
Floating Point Data Returned:
NONE
Integer Data Returned
Word High Byte Low Byte
0 STATUS WORD
1 Final Assembly Number 0 Final Assembly Number 1
2 Final Assembly Number 2 0