Understanding the MVI-ADM API MVI-ADM 'C' Programmable
Developer's Guide 'C' Programmable Application Development Module
Page 40 of 342 ProSoft Technology, Inc.
February 20, 2013
The backplane communication would be configured as follows:
Database address 0 to 479 will be continuously transferred from the module to
the processor. Database address 480 to 959 will continuously be transferred
from the processor to the module.
The Block Transfer Size parameter basically configures how the Read Data and
Write Data areas are broken down into data blocks (60, 120, or 240).
If Block Transfer Size = 60:
Vedere la pagina 39